The international residential code irc requires a self closing device on this door but we have no such requirement here in minnesota.
Irc required garage door.
R302 11 fireblocking item 4.
Any other exterior door has a threshold height limited to 7 inches.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
We used to but we ve since amended that requirement out of our code.
One example of a problem area is the entry door between the garage and the residence.
This all irc international residential code not seattle specific.
This door assembly is not specifically required to be fire rated.
If the door is not solid wood or steel honeycomb and at least 1 3 8 thick then it must have a 20 minute fire rating.
These doors shall also be equipped with a self closing device.
Wind resistant garage door and frame installation code reference.
One could make the argument that given the wording in irc 302 5 1 a fire rated door or its equivalent is required.
Door to house this is the only place where any fire rating is specified.
Dasma garage door wind load guide based on the 2000 2003 2006 international residential codes irc similar to other doors and windows the design and installation of garage doors and frames shall comply with the design wind load for the structure.
Openings in garage walls shall comply with section r302 5.
A remodeler doing a flip house changes out all the doors in the home to update the interior and replaces the old door to the garage with a hollow core interior door.
The international residential code table is similar.
May 6 2018 at 4 47 pm.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
26 gage sheet metal or another approved material they also can t open to the garage.
International residential code page 1 of 2 chapter 3 building planning section r302 6 2015 edition irc interpretation 04 16 issued 5 19 2016 re 15 04 16 r302 6 dwelling garage fire separation.
2018 irc section r311 3 1 restricts threshold height a required exit door in residences to 1 inches from the top of the the threshold to the floor or landing on each side of the door.
1 2 drywall is all that is required on the wall between the house and the garage and on walls that support rooms above the garage.
Doors separating the garage and living spaces shall be 1 3 8 solid wood solid or honeycomb core steel doors not less than 1 3 8 thick or 20 minute rated doors.
Means of egress doors in the irc.
The garage shall be separated as required by table r302 6.
By the way cutting a hole in the door to install a pet door flap voids the 20 minute rating.
Typically doors to breezeways.
These doors shall not open into a sleeping room.